Don’t risk your facility on unprotected wall sockets. Our ECB.S certified cabinets feature integrated power distribution, automatic charging shut-offs, and absolute fire containment for high-volume active charging.

Batrea Lithium-Ion Charging Cabinet

VDMA 24994:2024-08

Protection from both internal and external fire

ECB·S Certified

Independent Certification Body

NMC 90505 Tested

Tested on the most dangerous NMC batteries 9-0,5-0,5

Comprehensive Monitoring

Including 24/7 Remote Monitoring

Engineered Specifically For Active Charging

Statistically, the highest risk of thermal runaway occurs while a battery is plugged in. Batrea is not just a passive storage box—it is a sophisticated, active charging environment designed to manage heat, monitor power loads, and instantly isolate catastrophic failures.

Review Cabinet Specs

Integrated Power Supply

Fitted with internal multi-socket power distribution units (PDU) compliant with Singapore/UK Type G standards, allowing you to charge multiple batteries simultaneously.

Automatic Power Severance

If the internal multi-sensor detects a critical temperature spike (60°C), the system instantly cuts all charging power to the internal sockets to prevent further thermal escalation.

Overvoltage Protection

Internal charging strips feature strict overvoltage protection, shielding sensitive lithium-ion cells from grid surges and localized short circuits.

Continuous Heat Extraction

Active charging generates heavy thermal loads. The cabinet connects to standard DN100 extraction systems (30 m³/h minimum flow) to continuously cycle out dangerous heat during the charging cycle.

The Cost of Inaction

When an unprotected lithium-ion battery fails, you are not just managing a fire—you are managing a catastrophic business continuity event.

01

Thermal Runaway

When an NMC battery enters thermal runaway, internal temperatures may exceed 1000°C in seconds. Standard storage cabinets and sprinklers cannot contain nor extinguish lithium-ion chemical fires. They spread exponentially, causing multi-unit propagation.

02

Toxic Gas & Explosion

Failing batteries release dense, highly toxic, and explosive off-gasses before flames ever appear. If these gasses accumulate without compliant ventilation and extraction, a devastating pressure explosion is inevitable.

03

Liability & Compliance

Insurers and auditors are cracking down. Storing and charging batteries without proper certified containment measures exposes your facility to denied insurance claims and unacceptable liability risk.

Engineered for Absolute Containment

The Batrea cabinet provides an impenetrable barrier between a battery failure and your facility.

Fire Containment

Built with an EN 1143-1 compliant safe body and a multi-walled insulating compound door leaf to trap extreme temperatures inside.

Explosion Resistance

A robust 4-way locking bolt system and heavily reinforced hinges prevent structural failure and door breach during sudden pressure spikes.

Smoke Isolation

Specialized fire-resistant smoke seals and an automatic ventilation shut-off system secure the chamber, completely preventing toxic gas leakage.

Safe Charging

Tested safe for continuous charging operations inside the safe cabinet. Automatic shut-off engages instantly upon detection of critical temperatures.

Proactive Intelligence

The Batrea multi-detector sensor provides real-time oversight and clear escalation protocols.

Continuous monitoring of internal chamber conditions prevents a warning from becoming a disaster. Diagnostics feed directly into the physical control panel and your remote app dashboard. (*remote feature to be ready by end of 2026)

50°C
Warning Threshold Intermittent acoustic signal alerts nearby personnel to abnormal internal temperature rise. Visual LED indicator activates.
54°C
Continuous Alarm Temperature continues rising. Acoustic signal becomes continuous, requiring immediate intervention and assessment.
60°C
Critical Shutoff Event Critical hazard detected. Automatic ventilation flap mechanism immediately seals the cabinet. All charging power is severed.
60s
Door Security Alert Cabinet door left open longer than 60 seconds triggers a compliance alarm, ensuring containment protocols are maintained.
Batrea Safe - Control Panel

Certified Protection For Every Scale

Choose the capacity and fire rating that aligns with your operational payload and floor constraints.

batrea 1 I/O60 Cabinet

batrea 1 I/O60 Charging Vault

Art. B470001.01.03
  • Max Capacity: 3,000 Wh
  • Max load energy: 3,000 W
  • Ext. Dimensions (H×W×D): 754 × 711 × 762 mm
  • Weight: 294 kg
Request Quote
batrea 1 I/O30 Cabinet

batrea 1 I/O30 Charging Vault

Art. B470006.01.03
  • Max Capacity: 3,000 Wh
  • Max load energy: 3,000 W
  • Ext. Dimensions (H×W×D): 754 × 711 × 762 mm
  • Weight: 294 kg
Request Quote
batrea 2 I/O30 Cabinet

batrea 2 I/O30 Charging Vault

Art. B470007.01.03
  • Max Capacity: 9,000 Wh
  • Max load energy: 3,680 W
  • Ext. Dimensions (H×W×D): 1,269 × 733 × 762 mm
  • Weight: 450 kg
Request Quote
batrea 3 I/O30 Cabinet

batrea 3 I/O30 Charging Vault

Art. B470008.01.03
  • Max Capacity: 15,000 Wh
  • Max load energy: 3,680 W
  • Ext. Dimensions (H×W×D): 1,969 × 733 × 762 mm
  • Weight: 630 kg
Request Quote

Critical Compliance Specifications

Standardized safety features integrated across all Batrea charging vaults.

VDMA 24994 Tested Standard
DN100 Ventilation Connector
30 m³/h Min. Extraction Flow
EN 1143-1 Body & Door Compliance